Bone Grafts Research - Spine Fusion, Surgery, Procedure, Risks

Bone Grafts Research Today is a free monthly online journal that collates and summarizes the latest research about Bone Grafts, including details on spine fusion, surgery, procedure, risks.


Bone Grafts Research Today

Home

View Latest Issue

Information About Bone Grafts

Books on Bone Grafts

Advertising in Research Today

View Other Research Today Publications



Biomechanical characteristics of an implant used to secure semitendinosus-gracilis tendon grafts in a canine model of extra-articular anterior cruciate ligament reconstruction.

Lopez MJ, Spencer N, Casey JP, Monroe WT

Laboratory for Equine and Comparative Orthopedic Research, School of Veterinary Medicine, and the Department of Biological and Agricultural Engineering, Louisiana State University and AgCenter, Baton Rouge, LA 70803-8410, USA. mlopez@vetmed.lsu.edu

OBJECTIVE: To compare initial femoral fixation properties of a new implant, Graftgrab (GG), with 2 established methods of extra-articular femoral graft fixation, spiked washers (SW) and bone staples (ST). STUDY DESIGN: Experimental in vitro cohort study. METHODS: Canine semitendinosus-gracilis tendon grafts were passed through bone tunnels and fixed to the lateral surface of femoral condyles with spiked washers, bone staples, or new implant prototypes. The fixations were tested to failure with a single-cycle load at a rate of 50 mm/min. Failure and yield strength, stiffness, energy, and elongation were determined from load-displacement curves and failure modes were recorded. RESULTS: The graft failed midsubstance in 4 SW, 4 ST, and 1 GG fixations. In 3 SW, 3 ST, and 1 GG specimens, the graft slipped from the fixation. The graft ruptured at the clip (3) and the intra-articular (2) surface of the bone tunnel in the remaining GG specimens. There were no significant differences between fixation groups in femoral tunnel length, femoral width, or the mechanical properties evaluated. CONCLUSIONS: The initial in vitro mechanical properties of the new fixation implant are comparable with those of spiked washers and bone staples. CLINICAL RELEVANCE: The initial mechanical performance of the new implant tested in this study was similar to those of comparable, established implants. The new implant is novel and may be useful for human anterior and veterinary cranial cruciate ligament graft reconstruction fixation.

Published 9 August 2007 in Vet Surg, 36(6): 599-604.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2004-2008 Bone Grafts Research Today. All Rights Reserved.



Bone Grafts Research Today Archive:

Volume 1 (2004)
  Issue 1 (September)
  Issue 2 (October)
  Issue 3 (November)
  Issue 4 (December)

Volume 2 (2005)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 5 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)



Bone Grafts Books

Bone Grafts and Bone Substitutes: Basic Science and Clinical Applications

Bone Grafts and Bone Substitutes: Basic Science and Clinical Applications