Bone Grafts Research - Spine Fusion, Surgery, Procedure, Risks

Bone Grafts Research Today is a free monthly online journal that collates and summarizes the latest research about Bone Grafts, including details on spine fusion, surgery, procedure, risks.


Bone Grafts Research Today

Home

View Latest Issue

Information About Bone Grafts

Books on Bone Grafts

Advertising in Research Today

View Other Research Today Publications



The effect of femoral attachment location on anterior cruciate ligament reconstruction: graft tension patterns and restoration of normal anterior-posterior laxity patterns.

Zavras TD, Race A, Amis AA

Biomechanics Section, Imperial College London, Room 638, Mechanical Engineering Building, London, SW7 2AZ, UK.

The issue of the best place to attach an anterior cruciate ligament graft to the femur is controversial, and different anatomic or isometric points have been recommended. It was hypothesised that one attachment site could be identified that would be best for restoring normal anterior-posterior laxity throughout the range of knee flexion. It was also hypothesised that these different attachment sites would cause different graft tension patterns during knee flexion. Using six cadaver knees, an isometric point was found 3 mm distal to the posterior edge of Blumensaat's line, at the 10:30-11:00 o'clock position in right knees, at the antero-proximal edge of the anatomic ACL attachment. Anterior-posterior laxity was measured at +/-150 N draw force at 20-120 degrees flexion with the knee intact and after anterior cruciate ligament transection. The graft was placed at the isometric point, and AP laxity was restored to normal at 20 degrees flexion, then measured at other angles. Graft tension was measured throughout, and also during passive flexion-extension. This was repeated for four other graft positions around the isometric point in every knee. Laxity was restored best by grafts tensioned to a mean of 9 +/- 14 N, positioned isometrically and 3 mm posterior to the isometric point. Their tension remained low until terminal extension. Grafts 3 mm anterior to the isometric point caused significant overconstraint, and had higher tension beyond 80 degrees knee flexion. Small changes in attachment site had large effects on laxity and tension patterns. These results support an isometric/posterior anatomic femoral graft attachment, which restored knee laxity to normal from 20 to 120 degrees flexion and did not induce high graft tension as the knee flexed. Grafts attached to the roof of the intercondylar notch caused overconstraint and higher tension in the flexed knee.

Published 9 March 2005 in Knee Surg Sports Traumatol Arthrosc, 13(2): 92-100.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2004-2008 Bone Grafts Research Today. All Rights Reserved.



Bone Grafts Research Today Archive:

Volume 1 (2004)
  Issue 1 (September)
  Issue 2 (October)
  Issue 3 (November)
  Issue 4 (December)

Volume 2 (2005)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 5 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)



Bone Grafts Books

Graft vs. Host Disease, Third Edition

Graft vs. Host Disease, Third Edition